Worksaver LRHD-6 Spezifikationen Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
0000WS65:99900663: 3-119930211
3-1. GENERAL
This section provides installation instructions for
the IMT WorkSaver™ Crane. See Figure E-9
for specific winch remote control wiring for
cranes with manual swing and Figure E-14 for
those with power swing.
3-2. INSTALLATION
The mounting space required for the crane base
is 10" x 10" (25.4 x 25.4cm) with a square bolt
hole pattern measuring 8" x 8" (20.3 x 20.3cm).
Before determining the location for mounting,
keep in mind that the 5' version crane has a
horizontal reach from centerline of rotation of
62" (1.57m) and the 7' version has a reach of
85" (2.16m). Also important is that the crane
has a 346° (6.04 rad) rotation capability.
Using the holes in the base as a pattern, mark
the location of the four mounting holes as well
as the inside electrical access hole. Drill 11/16"
diameter holes at these five (5) locations. See
Figure C-1.
CAUTION
BEFORE DRILLING MOUNTING HOLES, CHECK
BELOW THE MOUNTING SURFACE FOR ANY
OBSTRUCTIONS, FUEL LINES, EXHAUST OR
ELECTRICAL COMPONENTS.
Locate the base with the rotation stop positioned
for your particular application which is normally
away from the most used working position.
Secure the base to the mounting surface using
four (4) 5/8-11, hex head, grade 5, cap screws;
eight (8) 5/8" flat washers and four (4) 5/8-11
self-locking, hex nuts. See Figure C-2.
After securing the base in position, feed the two
wires from the end of the mast through the
electrical access hole. Place the mast
assembly into the base, being careful not to
pinch the wires.
Once the crane is in place, run the positive feed
wire, with circuit breakers, along the truck
frame and connect to the starter side of the
starter solenoid. Secure this wire to the truck
frame using cable clamps at approximately 18"
(45cm) intervals. The negative lead wire must
be connected to a good ground on the truck
frame. Prepare the ground location by sanding
all paint or rust down to bare metal for maximum
ground contact. Secure this wire to the truck
frame using cable clamps at 18" (45cm)
intervals.
Figure C-1. MOUNTING DIMENSIONS Figure C-2. MOUNTING HARDWARE